    Plastic septic tank 7 m³ - for dry conditions

    First-class polypropylene tank with stainless steel reinforcements. Tank volume 7 m³.

    Product code:03-1

    Product description

    The large plastic three-chamber septic tank with a volume of 7 m³ is ideally suited for properties inhabited at once by up to 12 people. This includes two-generation houses, smaller pensions, as well as workshops and smaller operations. 

     

    The plastic three-chamber septic tank  is a flow-through tank with an installed system of separation baffles, designed for accumulation and partial treatment of wastewater from households. 

     
    By combining the NAUTILUS® three-chamber septic tank and a sand/gravel soil filter from our offer, you achieve a wastewater treatment efficiency of up to 95%, making it a full-fledged replacement for a wastewater treatment plant. 
     
    Moreover, the construction of the plastic septic tank is self-supporting, so during installation you do not need to encase it in concrete, saving both time and money. 
     
    A sophisticated system of optional structural modifications allows the tank to be placed at such a depth that you can easily connect it to the sewage system up to 110 cm below the ground level. 
     
    Plastic covers with a UV filter including locking mechanisms are included in the delivery.
     
    1. finished ground level   
    2. backfill with screened soil   
    3. quarry stone backfill   
    4. compacted bedding, quarry stone   
    5. ground level   
    6. cover   
    7. concrete anchor (only in presence of groundwater) 
    8. reinforcement steel  (only in presence of groundwater) 
    9. inlet DN 160  
    10. outlet DN 160
                   
    Length
    A (m)
    Length
    B (m)
    Installation depth
    C (m)
    Inlet depth
    D (m)
    Outlet depth
    E (m)
    Diameter
    F (m)
    Width
    G (m)
    Thickness
    H (m)
    4.3 4.8 1.7 0.45 0.5 1.4 1.9 0.1
                   

     

    1. finished ground level   
    2. backfill with screened soil   
    3. quarry stone backfill   
    4. compacted bedding, quarry stone   
    5. ground level   
    6. cover   
    7. concrete anchor (only in presence of groundwater)  
    8. reinforcement steel (only in presence of groundwater)  
                   
    Length
    A (m)
    Length
    B (m)
    Installation depth
    C (m)
    Inlet depth
    D (m)
    Outlet depth
    E (m)
    Diameter
    F (m)
    Width
    G (m)
    Thickness
    H (m)
    4.3 4.8 1.7 0.45 0.5 1.4 1.9 0.1